Product overview

 

Fire-resistant cables are designed to maintain electrical circuit integrity under specified fire-test conditions. They are used in circuits serving essential systems such as fire alarms, emergency lighting, smoke control and emergency power equipment.


Depending on the cable design, construction may include a mica-tape fire barrier, suitable insulation, an LSZH (low-smoke zero-halogen) outer sheath, metallic armor or mineral insulation.


These features address different requirements. Fire resistance concerns circuit integrity under defined fire conditions, flame retardancy concerns flame propagation, and LSZH properties concern smoke and halogen acid gas emissions. Compliance with one requirement does not automatically establish compliance with the others.


Typical buyers: Electrical cable distributors, importers, electrical contractors, EPC companies and fire protection system integrators.

 

 
  • Fire Resistant Main Electrical Cable
    The Fire Resistant Main Electrical Cable (NH-YJV) is the heavy-duty power counterpart to our control cables, designed to keep main power distribution lines operational during a fire emergency.
  • Fire-Rated Signal Control Cable
    When a fire breaks out, control systems must stay alive to activate sprinklers and emergency vents. Our Fire-Rated Signal Control Cable (NH-KVV) is engineered to maintain circuit integrity for 90...
  • XLPE Fire Resistant Power Cable
    NH-YJV
    Conductor:Compact stranded copper
    Fire Resistant Layer:2-3 layers fluorophlogopite mica tape
    Insulation:XLPE
    Sheath:Flame retardant PVC (or LSZH on request)
  • Fire Resistant STA Power Cable
    NH-VV22
    Conductor:Class 2 stranded copper
    Fire Resistant Layer:2-3 layers synthetic mica tape
    Insulation:PVC
    Inner Liner:Flame retardant PVC
  • Fire Resistant Power Cable
    NH-VV
    Conductor:Class 2 stranded copper
    Fire Resistant Layer:2 layers synthetic mica tape (25% overlap)
    Insulation:PVC
    Sheath:PVC
  • Fire Resistant STA Control Cable
    NH-KVV22
    Conductor:Copper
    Fire Resistant Layer:2-3 layers synthetic mica tape (25% overlap)
    Insulation:PVC
    Inner Liner:Flame retardant PVC
  • Fire Resistant Control Cable
    NH-KVV
    Conductor: Oxygen free copper
    Fire Resistant Layer: 2-3 layers synthetic mica tape (25% overlap)
    Insulation: PVC
    Sheath: PVC
 
Fire-resistant cable types and applications
 

Armored fire-resistant power cables
Designed for power circuits where additional mechanical protection is required. Armor type, conductor configuration and sheath materials should be selected according to the installation environment and electrical design.

 

Unarmored fire-resistant control cables
Used in control circuits where the installation design does not require metallic armor. Core count, conductor cross-section, shielding and fire-test requirements depend on the control system.

 

Fire-resistant alarm and signal cables
Used in fire detection, monitoring and other designated signal circuits. Buyers should confirm conductor configuration, electrical characteristics, shielding requirements and compatibility with the intended system.

 

Mineral-insulated cables
Constructed with metal conductors, compacted mineral insulation and a metal sheath. Selection depends on the specified cable design, termination requirements, installation conditions and applicable product standard.


The appropriate cable type depends on circuit function, rated voltage, conductor size, required fire performance, mechanical protection and installation conditions. These constructions should not be treated as interchangeable without checking the project specification.

 

Technical specifications
 

The following table identifies the main parameters buyers should confirm when selecting fire-resistant cables. Actual values must be taken from the manufacturer's datasheet for the selected model.

Technical parameter

Specification or selection requirement

Rated voltage

Confirm the rated voltage of the selected cable series

Conductor material

Copper or another specified conductor material

Conductor class

Class 1, Class 2 or Class 5, where applicable

Conductor cross-section

Specify the required nominal cross-sectional area

Number of cores

Confirm the required core count

Fire-resistant construction

Mica tape, mineral insulation or another tested design

Primary insulation

Confirm the material specified for the cable model

Outer sheath

LSZH or another specified sheath material, where applicable

Armor

SWA, STA, AWA or unarmored construction, subject to cable design

Operating temperature

Confirm the manufacturer's rated temperature range

Fire-test standard

Specify the applicable standard and required test conditions

Circuit integrity duration

Confirm the required duration and the corresponding test evidence

Minimum bending radius

Confirm the manufacturer's value for the selected construction

Cable length

Specify standard drum length or required cut lengths

Packaging

Confirm drum type, labeling and export packaging requirements

Final selection should be based on the applicable cable specification, installation requirements and verified product data rather than generic values.

 

Fire Resistant Main Electrical Cable

 

Materials and construction

Copper conductors
Conductor material, class, cross-section and electrical resistance requirements should be specified according to the selected cable design and applicable conductor standard.
Fire-resistant insulation system
Mica tape or mineral insulation may form part of the fire-resistant construction. The actual design and circuit integrity performance must be supported by the relevant product specification and test evidence.
Primary insulation and outer sheath
XLPE, LSZH compounds and other materials may be used depending on the cable type. Primary insulation and outer sheathing perform different functions and should be specified separately.
Armor and mechanical protection
Steel wire armor, steel tape armor or other suitable constructions may be available for selected cable types. For single-core AC cables, armor selection requires consideration of electromagnetic effects and the applicable electrical design requirements.

 

Standards and testing
 

The applicable standards depend on the cable type, intended application and project specification. A standard reference alone does not establish that a particular cable has passed the relevant test.

Standard

Main scope

IEC 60331 series

Circuit integrity testing under specified fire conditions

BS 6387

Fire-performance test requirements for cables within its scope

IEC 60332-1-2

Flame propagation testing of a single vertically installed insulated wire or cable

IEC 60332-3-22

Flame propagation testing of bunched cables under defined conditions

IEC 60754-1

Determination of halogen acid gas content from combustion of cable materials

IEC 61034-2

Measurement of smoke density from cables burning under defined conditions

IEC 60228

Conductor requirements for insulated cables

Quality control and inspection

Quality checks should follow the applicable product specification and inspection plan. Depending on the cable design, they may include conductor resistance, dimensional verification, insulation integrity and sheath material testing.


Fire-performance tests, flame propagation tests, smoke measurements and halogen acid gas tests should be documented where required. Routine tests, type tests and third-party witnessed tests should be identified separately.


Before placing an order, buyers should confirm which test reports, inspection records and conformity documents are available for the exact cable model. Claims of compliance should be supported by applicable reports or certificates.

 

Customization and OEM supply

 
 

Electrical configuration
Specify conductor material and class, cross-section, core count, rated voltage and other required electrical characteristics.

 
 

Cable construction
Confirm the fire barrier, insulation material, outer sheath, shielding and armor requirements according to the intended application.

 
 

Marking and packaging
Cable identification, meter marking, labels, drum lengths and cut lengths can be specified according to the manufacturer's available options.

 
 

OEM requirements
Private labeling, customized cable markings and project-specific documentation should be agreed upon before order placement. Available options and minimum order quantities require confirmation.

 

 

 
Bulk supply and delivery
 
01/

Order planning
Provide the cable specification, order quantity, required drum lengths and delivery schedule to support production planning.

02/

Quality documentation
Agree on the required test reports, inspection records, conformity documents and any third-party inspection arrangements before production or shipment.

03/

Export packaging
Confirm drum type, moisture protection, loading requirements and shipping arrangements according to the cable dimensions, transport conditions and destination requirements.

04/

Lead time and minimum order quantity
MOQ, production lead time and shipment schedules depend on the cable construction, order volume, testing requirements and current production capacity. Confirm these details in the supplier's quotation.

 

Frequently asked questions

 

 

Q: What is the difference between fire-resistant and flame-retardant cables?

A: Fire-resistant cables are designed to maintain circuit integrity under specified fire-test conditions. Flame-retardant cables are tested for their ability to limit flame propagation under defined conditions. Passing one type of test does not automatically demonstrate compliance with the other.

Q: What is the difference between IEC 60331 and BS 6387?

A: IEC 60331 addresses circuit integrity under specified fire conditions. BS 6387 specifies fire-performance test requirements within its scope, including designated test categories. Buyers should confirm the applicable edition, test conditions and supporting evidence for the selected cable.

Q: Are fire-resistant cables suitable for outdoor installation or direct burial?

A: Suitability depends on the cable's construction, sheath properties, moisture and UV resistance, mechanical protection and applicable installation requirements. Confirm that the selected model is suitable for the intended environment before ordering.

Q: What documents should buyers request?

A: Depending on the project, buyers may require a technical datasheet, applicable fire-test reports, routine test records, certificates of conformity and third-party inspection documentation. The availability and scope of each document should be confirmed with the supplier.

Q: What information is needed for a quotation?

A: Provide the cable type, conductor cross-section, core count, rated voltage, applicable standard, required fire-test performance, installation environment, order quantity, drum length, packaging requirements and delivery destination.

 

modular-1
Request a technical datasheet or quotation

Send your cable specification or project requirements for technical review and quotation.
Include the required cable construction, rated voltage, conductor size, core count, applicable standards, fire-test requirements, order quantity, packaging details and delivery destination.
The proposed cable configuration, compliance documentation, production lead time and commercial terms can then be confirmed against your requirements.

As one of the most experienced fire-resistant cables manufacturers in China, featured by quality products and low price. Please rest assured to wholesale customized fire-resistant cables made in China here from our factory. For quotation, contact us now.