Factory fire hydrant pump power supply. Residential area outdoor fire ring main. These fire power supply lines need direct burial. The cable must handle two things. Soil pressure and excavator damage. And the code requirement to keep power supply during a fire.
Our Fire Resistant STA Power Cable is an economy power cable with both fire resistance and armour. Its voltage rating is 0.6/1kV. It is the armoured version of NH-VV. It keeps a lower cost while providing strong mechanical protection.
The fire resistant layer is outside the conductor. We wrap 2 to 3 layers of synthetic mica tape. This ensures Class B fire resistance. 750°C for 90 minutes.
The core is the armour layer. Outside the inner liner is double layer galvanized steel tape. We use a gap wrapping method. This provides 10kN/m side pressure resistance. It effectively resists direct burial soil pressure and rodent bites.
The inner and outer sheaths work like this. The inner liner cushions the steel tape pressure. The outer sheath is black flame retardant PVC. We add UV stabilizers and anti corrosion ingredients. This is very suitable for direct burial.
This cable fully meets the requirements of GB 50217 power engineering cable design code for direct burial cables. The armour layer can serve as a return path for ground fault current. You do not need to lay an extra ground flat steel. The outer sheath passes the GB/T 2951.12 environmental stress cracking test. It has very good long term stability in direct burial soil.
Besides Class B fire resistance, the PVC sheath also meets single vertical flame retardancy. It self extinguishes. But note: NH-VV22 does not have Class A fire resistance. It is not suitable for very high rise buildings or nuclear power plants with extremely high requirements.
The conductor working temperature is 70°C. The minimum bend radius for armoured type is 15 times the cable outer diameter.
For direct burial, put 100mm of fine sand at the bottom of the trench. Put protection plates or red bricks on top of the cable. Then backfill with soil. Do not put the cable directly on rocks or hard surfaces. That will deform the armour layer under pressure.
Our Fire Resistant STA Power Cable is made with strict quality control. We have a dedicated quality control department. They do random checks. We have dedicated staff for after sales service. We accept third party inspection.
Technical Data Table
|
Parameter |
Value |
|
Product Name |
Fire Resistant STA Power Cable |
|
Conductor |
Class 2 stranded copper |
|
Fire Resistant Layer |
2-3 layers synthetic mica tape |
|
Insulation |
PVC |
|
Inner Liner |
Flame retardant PVC |
|
Armour |
Double layer galvanized steel tape |
|
Sheath |
Black flame retardant PVC (UV stabilized) |
|
Voltage Rating |
0.6/1kV |
|
Normal Working Temp |
70°C |
|
Fire Resistance |
Class B (750°C, 90 minutes) |
|
Side Pressure Resistance |
10kN/m |
|
Min Bend Radius |
15 x outer diameter |
|
Best Application |
Factory fire hydrant pumps, residential outdoor fire ring mains, direct burial fire power |