Fire Resistant Power Cable

Fire Resistant Power Cable
Details:
NH-VV
Conductor:Class 2 stranded copper
Fire Resistant Layer:2 layers synthetic mica tape (25% overlap)
Insulation:PVC
Sheath:PVC
Send Inquiry
Description
Send Inquiry
-

Small and medium buildings. Temporary fire facilities. Cost sensitive retrofit projects. These places need a cable. It must meet basic fire resistance requirements. It must keep power supply during a fire. It cannot be too expensive.

Our product is an economy fire resistant power cable. Its voltage rating is 0.6/1kV. It is a fire resistant upgrade of the VV power cable. It adds a mica tape fire resistant layer to the PVC insulation and sheath.

The conductor is Class 2 stranded copper conductor. This gives good conductivity and terminal crimping strength.

The core is the fire resistant layer. Outside the conductor, we wrap 2 layers of synthetic mica tape. The overlap rate is 25% or more. The mica tape sinters into a ceramic shell in a fire. It maintains insulation.

The insulation and sheath are PVC. The normal working temperature of PVC is 70°C. This is good enough for ordinary fire control circuits.

Compared to the same size NH-YJV, the material cost of NH-VV is 15% to 20% lower. This is because PVC material itself is cheaper than XLPE. And the processing energy is lower.

It meets GB/T 19216.21 Class B fire resistance standard. 750°C for 90 minutes. In a 750°C flame with rated voltage applied, the fuse does not trip for 90 minutes. Note: NH-VV generally does not claim to pass Class A 950°C fire resistance. Because at high temperatures, the PVC sheath produces a lot of HCl gas. It also softens. This may affect the mica tape structure.

The conductor working temperature is 70°C. Short circuit temperature is 160°C. Minimum bend radius is 10 times the cable outer diameter for non armoured. For armoured, it needs 15D.

The current carrying capacity of NH-VV is about 15% lower than NH-YJV. This is because of 70°C working temperature versus 90°C. When sizing, correct the current carrying capacity for 70°C. We suggest not using it in crowded enclosed spaces. The HCl gas produced when burning is toxic. It also corrodes equipment.

The Fire Resistant Power Cable is made in our factory. Our factory area is 48,000 sq meters. Building area is 24,000 sq meters. We have 245 employees. We have worked with global brands. We meet local environmental regulations.

 

Technical Data Table

 

Parameter

Value

Product Name

Fire Resistant Power Cable (NH-VV)

Conductor

Class 2 stranded copper

Fire Resistant Layer

2 layers synthetic mica tape (25% overlap)

Insulation

PVC

Sheath

PVC

Voltage Rating

0.6/1kV

Normal Working Temp

70°C

Short Circuit Temp

160°C

Fire Resistance

Class B (750°C, 90 minutes)

Material Cost vs NH-YJV

15-20% lower

Min Bend Radius

10 x outer diameter (non armoured), 15D (armoured)

Best Application

Small buildings, temporary fire facilities, cost sensitive retrofits

Factory

48,000 sq m, 245 employees

 

Hot Tags: fire resistant power cable, China fire resistant power cable manufacturers, XLPE Fire Resistant Power Cable, Fire Resistant Control Cable, fire resistant cables, Fire Resistant STA Control Cable, Fire Resistant Power Cable, Fire Resistant STA Power Cable

Send Inquiry